Abstract

Background:The aim of this meta-analysis was to evaluate the diagnostic value of lung ultrasound (LUS) in comparison to chest radiography (CXR) in children with pneumonia.Methods:Computer-based retrieval was performed on PubMed and EMBASE. Quality was evaluated according to the quality assessment of diagnostic accuracy studies-2, and Meta-Disc was adopted to perform meta-analysis. Heterogeneity was assessed using Q and I2 statistics. The pooled sensitivity, specificity, and diagnostic odds ratio (DOR) with 95% confidence intervals (CIs) as the primary outcomes were calculated for each index test.Results:Twenty two studies with a total of 2470 patients met the inclusion criteria. Our results showed that the pooled sensitivity, specificity, and DOR for children with pneumonia diagnosed by LUS were 0.95 (95% CI: 0.94 to 0.96), 0.90 (95% CI: 0.87 to 0.92), and 137.49 (95% CI: 60.21 to 313.98), respectively. The pooled sensitivity, specificity, and DOR for pediatric pneumonia diagnosed by CXR was 0.91 (95% CI: 0.90 to 0.93), 1.00 (95% CI: 0.99 to 1.00), and 369.66 (95% CI: 137.14 to 996.47), respectively. Four clinical signs, including pulmonary consolidation, positive air bronchogram, abnormal pleural line, and pleural effusion were most frequently observed using LUS in the screening of children with pneumonia.Conclusions:The available evidence suggests that LUS is a reliable, valuable, and alternative method to CXR for the diagnosis of pediatric pneumonia.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call