Abstract
Placing instrumentation into the ilium has been shown to increase the biomechanical stability and the fusion rates, but it has some disadvantages. The diagonal S2 screw technique is an attractive surgical procedure for degenerative lumbar deformity. Between 2008 and 2010, we carried out long fusion across the lumbosacral junction in 13 patients with a degenerative lumbar deformity using the diagonal S2 screws. In 12 of these 13 patients, the lumbosacral fusion was graded as solid fusion with obvious bridging bone (92%). One patient had a rod dislodge at one S2 screw and breakage of one S1 screw and underwent revision nine months postoperatively. So, we present alternative method of lumbopelvic fixation for long fusion in degenerative lumbar deformity using diagonal S2 screw instead of iliac screw.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.