Abstract

ABSTRACT Objective To assess postoperative outcomes following lumbar microdiscectomy (LMD) with and without the use of a dynamic intralaminar device IntraSPINE ® . Methods A non-randomized single-surgeon retrospective analysis. Consecutive elective surgery was performed on patients with lumbar disc disease over a 16-month period. The study group was determined by electronic theatre database. Ninety-two (62 LMD and 30 ILD) of the 95 eligible patients were included in the study, with three being excluded due to incomplete data sets. The pain scores were assessed pre- and postoperatively using a 4-point scale (0 – pain free; 1 – mild; 2- moderate; 3 – severe). Results The reduction in postoperative leg pain was similar (LMD 1.9 vs. IntraSPINE® 1.8) but the reduction in postoperative back pain was greater in the IntraSPINE® group (LMD 0.5 vs. IntraSPINE® 1.0; p = 0.17). Early recurrence of disc herniation (< 8 months) was lower in the IntraSPINE® group (6.7% vs. 19.4%; p = 0.097). The need for revision surgery was significantly lower in the IntraSPINE® group (p = 0.015). None of the IntraSPINE® recurrences required revision surgery, compared to 97% of the recurrences in the LMD group. Conclusions This case series raises the possibility that in selected patients, the use of the IntraSPINE® may improve back pain and reduce recurrent disc herniation/revision surgery rates in lumbar microdiscectomy. A prospective randomized trial on the use of the IntraSPINE® should be considered, given the clinical and cost implications of revision surgery. Level of Evidence IV; Case series.

Highlights

  • The IntraSPINE® is a dynamic intralaminar device produced by Cousin Biotech, and indicated for use in lumbar spine surgery

  • All titles and abstracts retrieved in the search were screened, to determine the current literature on IntraSPINE® use in patients with lumbar intervertebral disc herniation treated with lumbar microdiscectomy

  • There was an improvement in back pain after lumbar microdiscectomy in 49 patients (53.3%): 20 patients (66.7%) in the IntraSPINE® group and 29 patients (46.8%) in the LMD group

Read more

Summary

Introduction

The IntraSPINE® is a dynamic intralaminar device produced by Cousin Biotech, and indicated for use in lumbar spine surgery. It is made from medical dimethyl siloxane with a polyethylene terephthalate covering, with the anterior part being designed to perfectly fit the intralaminar space. It is sold in five different sizes (8, 10, 12, 14, 16 mm) and is coated with silicone to prevent fibrosis and adhesions surrounding the spinal structures and the ligamentum flavum. A unilateral minimally invasive approach is recommended.[3]

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.