Abstract

To date, Lugol chromo-endoscopy is the reference technique to detect an esophageal neoplasia in patients with prior esophageal squamous-cell carcinoma (ESCC), but is not easy to perform without general anesthesia, which can limit its use in routine practice. The objective of this study were to compare the accuracy of white light, narrow band imaging (NBI), and Lugol to detect esophageal neoplasia in patients with a history of cured ESCC, in a prospective study. Thirty patients were prospectively included between June 2006 and June 2009. They all had a history of cured ESCC. Esophageal mucosa was examined first using white light, second NBI, and third after Lugol staining. Histology was obtained in all abnormalities detected by white light, NBI, and/or Lugol. Five neoplastic lesions in five different patients were identified at histology, four cancers, and one high-grade dysplasia. NBI and Lugol both detected all esophageal neoplastic lesions, whereas white light detected the four cancers but missed the high-grade dysplasia. In this feasibility study, NBI and Lugol both detected all identified esophageal neoplasia in very high-risk patients of ESCC. This result suggests that NBI could be used instead of Lugol to detect an esophageal neoplasia in patients with high risk of ESCC, but needs to be confirmed in a larger study.