The near-field earthquake ground motion is characterized by high peak accelerations and velocity pulses with long period components as well as large ground displacements. Such characteristics are responsible for severe damages to flexible structures. The peak ground acceleration occurs in the form of a shock, rather than a gradual build-up. As a result, passive dampers may not dissipate energies quick enough to prevent a serious damage to structures. Recently, a resetting or switching semi-active stiffness damper (RSASD or SSASD) and a semi-active electromagnetic friction damper (SAEMFD) have been shown to be effective in reducing the structural response due to dynamic loads. In this paper, the performance and effectiveness of these two semi-active hybrid isolation systems are studied extensively for base-isolated buildings subject to near-field earthquakes. Numerical results clearly demonstrate that these two semi-active dampers are effective in protecting the integrity of base-isolated structures during near-field earthquakes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.