A double crystal, multilayer monochromator was designed and fabricated for a wiggler beamline at the Cornell High Energy Synchrotron Source (CHESS). The monochromator consists of an internally water-cooled first substrate and a fixed-radius sagittally focusing second substrate, each coated with a multilayer consisting of 100 bilayers of Tungsten/Carbon with a 27 angstrom d-spacing. The wide energy bandpass of this multilayer along with sagittal focusing provides the best available flux for time resolved experiments. A flux 100 times that of conventional silicon monochromators is possible and allows for a finer time resolution for the crystal growth studies on this beamline. For other experimental uses, the higher intensity allows for more rapid data collection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.