Abstract
This paper describes the factors governing the Performance Efficiency (PE) of Indium Antimonide Charge Injection Devices (CID) arrays. Factors influencing PE in both line and area arrays are considered and compared to experimental results. An important factor re-lates to the signal charge loss of a dual gate array operating in the charge sharing mode (CSM). The chief advantages of the CSM are that it overcomes charge transfer problems that might be present in practical arrays, and it is believed to be radiation damage resistant. The chief limitation is that only the charge residing under the sensing gate of the dual gate site is read out. This loss can be lessened by designing the sensing gate to be a large fraction of the total storage area. Performance data of lx32, lx64 line arrays, 24x16 and 32x32 dual gate area arrays are presented. Line arrays FE up to 56 percent, responsivity variation below 10 percent, and D* of about 3x1011 cm HZ½/watt have been measured.© (1979) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.