Abstract

This paper presents studies conducted in an indoor exposure chamber, on the detection and mapping of chemical concentrations using open-path FTIR (Fourier Transform Infrared) spectroscopy and computed tomography. A vertical flow indoor air chamber having roller tracks at the periphery was used. The source and detector of an open-path FTIR spectrometer were mounted on separate tables place on the tracks. Sulfur hexafluoride was injected from the floor of the chamber and the plume was scanned using the FTIR spectrometer. Different ray configurations were used to scan and map the plume on a 2D plane. To test the validity of the FTIR/computed tomography system for mapping gases, point samples from within the chamber were drawn remotely from ports and were analyzed using an electron capture detector. The concentrations indicated by the gas samples at different points were compared to the tomographically mapped concentrations. A comparison of mapped concentrations with point sampled concentrations were made with respect to position, and concentration of the chemical peak. A comparison of different algorithms for mapping chemical concentrations was performed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.