Abstract
An airborne infrared (IR) line-scanner and a Fourier transform infrared (FT-IR) spectrometer operating in the 3- 5micrometers and 8-12micrometers spectral regions provide a rapid wide- area surveillance capability. The IR scene containing target vapors is mapped remotely with the wide fields of view (FOV) multi-spectral IR line-scanner using 14 bands. The narrow FOV FT-IR spectrometer permits remote verification of target vapor plume contents within the IR scene. The IR image and FT-IR interferogram analysis supply a near real-time detection that provides visual monitoring of potential downwind vapor hazards. This capability is demonstrated using the target vapor methanol. An active mono-static FT-IR configuration furnishes ground-truth monitoring for methanol released from an industrial stack and a nearby ground-level area. The airborne and ground-truth results demonstrate the usefulness of this approach in alerting first responders to potential downwind vapor hazards from an accidental release.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.