Abstract

We present the results of a DARPA sponsored study on the application of Focused Ion Beam (FIB) systems to metrology in advanced lithography for production and process development. Data on top-down measurements, on the effects of FIB imaging, and on milling strategies for cross-sectional preparation are presented for fine-line resist structures. In addition, some preliminary aspects of Ga contamination are addressed in the context of the residual dose and concentration leftover from FIB processing. A standard deviation of 8 nm for the measured line width was observed, which makes FIB metrology competitive with the more established technique of CD SEM analysis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.