The electron beam exposure systems (EBES) currently used for photomask fabrication have been designed to operate to positional accuracies of ∓ 0.031 micron over an address range of 0.20 to 1.00 micron. The tuning, calibration and characterization of these systems has required an exacting and time consuming series of tests. A standard test array, MARKET A15, has been developed which enables full system characterization with only a thirty minute master generation time'and four hours analysis. System parameters such as linewidth control, resolution, registration, absolute accuracy and pattern scale accuracy can be determined from a single plate. The tests are composed of a series of exposures designed for analysis under an optical microscope along with a second group requiring reinsertion of the plate into EBES for "self-analysis". This array can be used as a basis for tuning, monitoring and multiple systems calibration of EBES or EBES-like rastor scan systems, A discussion of tests and techniques demonstrates how several EBES type systems in Western Electric and Bell Laboratories have been brought into mutual compatibility.