Abstract

AbstractThis paper applies the proportional‐integral (PI) observer in connection with loop transfer recovery (LTR) design for continuous‐time systems. We show that a PI observer makes it possible to obtain time recovery, i.e., exact recovery for t →∞, under mild conditions. Based on an extension of the LQG/LTR method of proportional (P) observers, a systematic LTR design method is derived for the PI observer. Our recovery design method allows time recovery and frequency (normal) recovery to be done independently. Furthermore, we give explicit expressions for the recovery error when asymptotic recovery cannot be obtained. A design example demonstrates the advantages of time recovery in the non‐minimum phase case.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.