Abstract

A high voltage DC feeding system, which consists of higher-voltage feeders and DC-DC converters in addition to an existing feeding circuit, is assumed to improve the performance of power supply to trains without changing the nominal voltage of contact lines and onboard traction systems. In this system, the method for controlling the converter is an important element which must be taken into consideration to maximize energy savings. In this paper, we propose a converter control method to make the voltage ratio constant between the contact line and the higher-voltage feeder. In this paper, the high voltage DC feeding system with this converter control method is called a "DC-AT feeding system." We evaluated the energy savings of this system through simulation, and case studies on a model line confirmed that this system can reduce energy consumption by 4.5% at most, and on average 3.5%, compared to conventional DC feeding systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.