Abstract

This paper presents a systematic approach for turning the external area of a nonlinear power system model into a set of linear parameter-varying (LPV) models. The aim is to extend the scope of linear input-output equivalencing techniques by including some tunable parameters. In particular, the LPV models are designed to cover the changes in operating conditions that occur following the shutdown of generators. After partitioning the external area into multiple clusters, the dynamic behavior of a cluster is aligned to a new situation by scaling the inertia constant of its generators. The construction of a LPV model requires the assessment of the related linear cluster model for different values of the scale factor. A polynomial structure is subsequently fitted in the least-squares sense with respect to the collection of linear models. The quality of the LPV modeling approach is assessed on the IEEE 118-bus system model by studying multiple ways to disconnect generators from a cluster.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.