Abstract
Active power control (APC) refers to a mode of operation where the wind turbine tracks a desired power reference command. It enables wind farms to perform frequency regulation and to provide ancillary services in the energy markets. This paper presents a linear parameter varying (LPV) approach for APC. The multiple-input, multiple-output controller builds upon a previous gain-scheduled design. An LPV controller is designed to coordinate the blade pitch angle and generator torque, which are standard inputs to a utility scale turbine. The objective is to track a given power reference command while also minimizing the structural loads. The controller has parameter dependence on the wind speed and the power output. The LPV approach, in contrast to the previous adhoc gain scheduled design, provides (in theory) guarantees on closed-loop stability and performance. This allows the turbine to be operated smoothly anywhere within the power / wind speed envelope. The performance of this LPV design is evaluated using high fidelity simulations. The robustness of the LPV system is analyzed using the theory of integral quadratic constraints (IQCs).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.