Abstract
The low-velocity, low-energy impact response of a mineral and elastomer modified polypropylene was characterised by instrumented falling-weight impact testing of plates with annular clamping. Most of the impact tests were performed at −30 °C with incident impact velocities in the range 1.0–4.4 m/s, and with plate thicknesses in the range 2.0–3.9 mm. The following factors were investigated: moulding conditions (mould temperature, melt temperature, holding pressure), striker geometry, clamping, plate surface texture, melt flow weld lines and paint. The occurrence of brittle fracture was affected by all these factors, except the moulding conditions. Reducing the striker hemisphere diameter or changing to a flat striker induced brittle fracture. Removing the annular clamping led to a more brittle response. Plates with a weld line were more brittle than standard plates. The surface texture caused brittle fracture when the textured side was in tension under the striker. The paint induced brittle fracture at −30 °C, but no adverse effect of the paint was observed at 20 °C.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.