Abstract

With the anticipated retirement of Space Shuttles in the next few years, the re-supplying of short-lifetime sensors on the International Space Station (ISS) will be logistically more difficult. Carbon Monoxide (CO) is a well-known combustion product and its absence in a fire and post-fire environment is a reliable indicator for mission specialists that the air quality is at a safe to breathe level. We report on the development and performance of a prototype compact CO sensor, based on the PHOTONS platform [1], developed for the ISS based on tunable diode laser absorption spectroscopy (TDLAS). A CO absorption line at ~4285 cm<sup>-1</sup> is targeted using a distributed-feedback (DFB) laser diode operating at room temperature. A custom designed Herriott multipass cell 16cm long, with an effective path length of 3.7 m is employed. Mechanical, optical and electronics systems are integrated into a compact package of dimensions measuring 12.4"x 3.4"x 5". Power consumption is less than 1 W, enabling prolonged battery life. A detection limit of 3 ppm is achieved when performing 40 second long temperature scans. A recent initial test at NASA-JSC was successful. Future improvements include the reduction of the sampling volume, scan time and an improved CO minimum detection limit.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call