Abstract

A vialess E-band Lange coupler is presented. The design combines a novel `pseudo-dot' termination with impedance matching techniques. The multiple stage impedance matching network technique is used to design a 50 Ω Lange coupler. The `pseudo-dot' termination provides a suitable load to the isolation port, avoiding via connection to ground, thus reducing the cost of the fabrication process. The design achieves better than 2 dB insertion losses in the through and coupled paths with <;0.8 dB amplitude and ±2° phase errors for the entire E-band.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.