Abstract
PurposeThe industrial robot has high repeatability but low accuracy. With the industrial robot being widely used in complicated tasks, e.g. arc welding, offline programming and surgery, accuracy of the robot is more and more important. Robot calibration is an efficient way to improve the accuracy. Previous methods such as using coordinate measurement machines, laser trackers or cameras are limited by the cost, complex operation or the resolution. The purpose of this paper is to propose an approach and calibration equipment to address these issues.Design/methodology/approachThe proposed method relies mainly upon a laser pointer attached on the end‐effector and single position‐sensitive devices (PSD) arbitrarily located on the workcell. The automated calibration procedure (about three minutes) involves aiming the laser lines loaded by the robot towards the center of the PSD surface from various robot positions and orientations. The localization is guaranteed by precise PSD feedback servoing control, which means physically the intersections of each pair of laser lines (virtual lines) are on the same point. Based on the untouched single‐point constraint, the robot joint offset calibration is implemented. Using the authors' proposed approach, a portable, low‐cost, battery‐powered, wireless and automated calibration system was implemented. Error analysis was conducted on the system.FindingsThe localization error of the developed calibration system is within 2 μm. The errors in joint space are magnified in PSD plane, and consequently the resolution in the joint space is improved. The standard deviation of the identified parameters was small (10‐2), indicating the stability of the calibration method. Both simulation and experimental results verify the feasibility of the proposed method and demonstrate the developed calibration system can identify joint offset with uncalibrated laser tool parameters.Originality/valueThe paper shows how a portable calibration system for joint offset of industrial robots was developed and how the goal of fast, automated, low‐cost, portable, and high precision calibration methods for joint offset was achieved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.