Abstract
Different electric circuits for triggering the switch with a trigger unit based on an auxiliary glow discharge are discussed. Most attention is concentrated on the recent experimental results on low voltage triggering of the switch and on the mechanisms for the main discharge initiation under the action of the trigger pulse. Due to modifications in the trigger electric circuit, the switch is triggered starting from a voltage of 50 V at a current level in the trigger circuit of 10 mA. With a voltage of 200-250 V and a trigger current of about 0.25 A, the delay time to triggering does not exceed 200 ns.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.