Abstract

In order to realize the low vibration design, variable leakage flux permanent magnet (VLF-PM) motor is investigated and purposefully optimized. Firstly, the variable flux characteristics of the VLF-PM motor are studied in detail. Then the electromagnetic vibration characteristics of the VLF-PM motor under different operating conditions are analyzed. On this basis, key electromagnetic force harmonics caused by the vibration at typical operating conditions and torque performances are selected to be optimized. By the adoption of multi-objective optimization, low radial electromagnetic force (REF) and high output torque can be achieved. Both simulation and experimental results verify the effectiveness of the reduced vibration design of LCF-PM motors, which provides a potential research path for the low vibration design of PM motors, especially multi-mode PM motors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.