Abstract
Experimental results related to the initiation of damage in Z-fiber truss-reinforced sandwich panels are presented. Two different orientations of pin angles are considered. A pendulum-type impactor is used to impart very low levels of impact energy. Threshold energy levels at which the observable damage initiation occurs are determined. Nondestructive evaluation studies conducted prior to the impact are compared with the post-impact status of the panels for assessing the type and magnitude of the damage. These studies include ultrasonic inspection, microscopic inspection and acoustic emission tests. Damage is also evaluated by carrying out vibration tests before and after impact. Static indentation tests are carried out to compare with low velocity impact tests. Effects specific to the impact phenomena are studied by comparing the load displacement characteristics. Compression after impact characteristics are also evaluated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.