Abstract

Abstract This study compared the effects of conventional thawing methods (water immersion thawing (WIT, (25±1) °C), natural air thawing (AT, (25±1) °C, relative humidity (RH) (65±2) per cent), refrigerator thawing (RT, 4 °C, RH (80±2) per cent) and low-temperature (LT) combined with high-humidity thawing (LT, –1 °C to 1 °C (LT–1–1), 2–4 °C (LT2–4), 5–7 °C (LT5–7) and 8–10 °C (LT8–10), RH≥95 per cent) on the water-holding capacity, lipid oxidation and biochemical properties of Portunus trituberculatus (P. trituberculatus) myofibrillar protein. The results showed that WIT and AT significantly decreased the water-holding capacity while dramatically increasing lipid oxidation, protein oxidation and degeneration, resulting in serious P. trituberculatus quality deterioration. High humidity was beneficial for P. trituberculatus thawing. The thawing time of P. trituberculatus under the conditions of LT2–4 was only 39.39 per cent of that of conventional air thawing at 4 °C (RT), and the LT2–4 samples not only maintained better water-holding capacity but also had an obviously reduced degree of lipid oxidation, protein oxidation and denaturation. Thawed samples LT2–4 and LT5–7 provided better maintenance of P. trituberculatus quality than the LT–1–1 and LT8–10 samples. The best quality was exhibited after thawing at 2–4 °C. The levels of thiobarbituric acid reacting substances, carbonyl content and surface hydrophobicity observably decreased in these samples, while the total sulfhydryl contents dramatically increased compared to those of conventionally thawed samples, indicating lower lipid oxidation and protein oxidation. Moreover, the Ca2+-ATPase activity of the sample thawed at 2–4 °C (2.06 μmol Pi/mg prot/h) was markedly higher than that of samples subjected to WIT and AT. The product qualities observed after thawing at –1 °C to 1 °C, 5–7 °C and 8–10 °C under LT were comparable to that observed by RT. Considering its thawing efficiency and product quality, LT is a suitable method for the thawing of P. trituberculatus, and the ideal thawing conditions were LT at 2–4 °C.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.