Abstract

Utilization of the direct anterior approach (DAA) for total hip arthroplasty (THA) has been steadily increasing in recent years. While the DAA may offer some benefits compared to other approaches, there are still risks involved including relatively higher rates of periprosthetic femur fractures, especially when combined with cementless femoral stem use. The purpose of this study is to evaluate the early postoperative femoral complications with a short triple-wedge tapered stem used in primary THA via a DAA. A retrospective review was conducted of the arthroplasty registry of our institution from April 2022 to August 2023 to identify patients who underwent a primary THA via a DAA with the Short Medacta Stem (SMS) (Medacta International, Castel San Pietro, Switzerland). Patients were excluded if the stem was used for a revision surgery, they were within 90 days of surgery, or they refused research consent. Inclusion criteria was met in 262 patients (302 hips). Data was collected after reviewing the chart, and reports and radiographic measurements, including Dorr type and canal fit ratios, were obtained from preoperative and postoperative radiographs, respectively. A total of 302 total hips were included, 161 patients were male (53.3%) and 141 were female (46.7%), with an average age of 66.5 years (27-88, +/- 10.7 years). Average follow up was 0.3 years (range, 0.05-1.71 years). The majority of patients had a Dorr B femur (81.7%). The Median stem size used was an 8 (range, 2-15), and 89.4% of those had a collar. Average canal fill ratio was 0.83 (range, 0.43-0.98, +/- 0.07). Overall, there were two Vancouver B2a periprosthetic femoral shaft fractures (0.66%) that required revision surgery to a modular stem. In addition, there were two Vancouver Ag greater trochanteric fractures (0.66%) with acceptable alignment that did not require revision surgery. Demographic information about the patients with femoral complications is summarized in Table I. Average age of patients with femoral complications was 69.5 years, with an average canal fit ratio of 0.88. We found that the triple-wedge implant had a low rate of early femoral complication in primary THA from an anterior approach and is safe for use in THA from a DAA. More follow up is needed to evaluate continuing implant survivorship and patient outcomes.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call