Abstract

Hot snare excision using electrocautery is widely used for large colorectal polyps (>10mm); however, adverse events occur due to deep thermal injury. Colorectal polyps measuring 10-14mm rarely include invasive cancer. Therefore, less invasive therapeutic options for this size category are demanding. We have developed hot snare polypectomy with low-power pure-cut current (LPPC HSP), which is expected to contribute to less deep thermal damage and lower risk of adverse events. This study aimed to evaluate the efficacy and safety of LPPC HSP for 10-14mm colorectal polyps, compared with conventional endoscopic mucosal resection (EMR). In this multicenter, retrospective, observational study, clinical outcomes of EMR and LPPC HSP for 10-14mm nonpedunculated colorectal polyps between January 2021 and March 2022 were compared using propensity score matching. We identified 203 EMR and 208 LPPC HSP cases. After propensity score matching, the baseline characteristics between the groups were comparable, with 120 pairs. The en bloc and R0 resection rates were not significantly different between EMR and LPPC HSP groups (95.8% vs 97.5%, P=0.72; 90.0% vs 91.7%, P=0.82). The rates of delayed bleeding and perforation did not differ between the groups. Compared with conventional EMR, LPPC HSP showed a similar resection ability without an increase in adverse events. These results suggest that LPPC HSP is a safe and effective treatment for 10-14mm nonpedunculated colorectal polyps.