Abstract

We report a low-power-loss and high voltage X-ray tubes with a graphite nanospines (GNS) cold cathode. The cathode is encapsulated in a glass tube having a Beryllium window with a Tantalum film to generate X-rays. The internal tube pressure was below 10 −7 Pa and a tube current exceeding 1 mA at a tube voltage of 22.9 kV was observed in the fabricated X-ray tube. The tube current dispersion, defined as standard deviation/mean ( σ/mean), was relatively small at 2.4%. An X-ray radiation dose rate exceeding 5 Sv/h was obtained from the X-ray tube and the radiation dose rate dispersion was also small ( σ/mean=0.3%). As an application of the X-ray tube, we demonstrated radiography for the rapid inspection of organic products.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.