Abstract

In this paper, the effects of inverter harmonics on motor current fault signatures are studied in detail. It is theoretically and experimentally shown that the fault signatures caused by the inverter harmonics are similar and comparable to those generated by the fundamental harmonic on the line current. Theoretically-derived extended relations including bearing fault, eccentricity, and broken rotor bar relations are found to match experimental results. Furthermore, it is observed and reported that the asymmetries on the rotor caused by broken rotor bars increase the amplitude of even harmonics. To confirm these claims, bearing, eccentricity, and broken rotor bar faults are tested and the line current spectrum of each faulty motor is compared with the healthy one. The proposed additional fault data are expected to contribute positively to the inverter-fed motor fault decision making algorithms.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call