Abstract

The low-ohmic resistance measurement capabilities of the Van Swinden Laboratorium, National Institute of Standards and Technology, and the Federal Office of Metrology (METAS) were compared using a set of resistors with values 100 mΩ, 10 mΩ, 1 mΩ, and 100 μΩ, respectively. The measurement results of the three laboratories agree extremely well within the respective measurement uncertainties with the comparison reference value. Careful transport of the resistors was crucial for achieving this result. Still, some of the resistors showed steps in value at each transport which likely relates to the construction of the resistance elements of these resistors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.