This paper describes the completion of laboratory development work on a 765kV low-loss pipe-type AC transmission cable, employing oil-impregnated laminar insulation, comprising cellulose papers with a polypropylene film (PPP). Splice design and testing are emphasized. Additional testing of Sample 1 is described, as well as completed testing of Sample 2 involving two different splice designs. The economic impact of this new cable is considered. Test results demonstrate the quality and stability of the design.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.