The Associated Proton beam Experiment Platform (APEP) beamline is the first proton irradiation facility to use naturally-stripped protons which come from H-beams interacting with the residual gas in the linac beampipe at CSNS. The stripped beam current, which is in the order of 0.1% of the original H-beam and approximately 10 μA, should be measured precisely to provide the proton number for irradiation experiments. Therefore, a low-intensity beam current measurement system was developed with considerations to eliminate the external interferences. An anti-interference design is adopted in this system with an elaboration of probes, cables and electronic low-noise technology to minimize the impact of environmental noise and interferences. This improves the signal-to-noise ratio and enables a more precise measurement of the microampere level pulsed beam current. The system was installed and tested during the summer maintenance in 2021 and 2022. It shows a good agreement with the measurement of the Faraday cup.