Abstract
Abstract : A low inductance gaseous switch tube has been designed and tested which permits high current (>150,000 amp) switching of power at potentials up to 20 kv without deterioration of electrodes due to current pinching. The switch is so designed that triggering is accomplished externally with very low (<0.1 micro sec) time jitter over a wide range (5 - 20 kv) of operating voltages. (Author)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.