Abstract

In order to predict the useful lifetime of semiconductor detectors which operate in the Earth's trapped radiation belts, the effects of damage by 50 keV, 200 keV, 600 keV and 1 MeV protons on silicon, surface-barrier, transmission detectors have been studied for fluences from 1010 to 1014 protons/cm2. Detector current, noise and capacitance increased with fluence with significant increases occurring after 1013 protons/cm2. Bias-voltage-dependent multiple peaking was observed with Am-241 alpha particles. The effects of damage by protons with these low energies are significantly reduced in transmission detectors if the protons enter the rear, aluminum contact rather than the front, gold contact.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.