Abstract

Implementing personalization protocol in clinical routine necessitates diverse low-dose PET/CT scan protocols. This study explores the clinical feasibility of one-third (1/3) dose regimen and evaluates the diagnostic image quality and lesion detectability of BMI-based 1/3-injection doses for 2-[18F]FDG PET/CT imaging. Seventy-four cancer patients underwent total-body 2-[18F]FDG PET/CT examination, with 37 retrospectively enrolled as full-dose group (3.7 MBq/kg) and 37 prospectively enrolled as the 1/3-dose group (1.23 MBq/kg). The 1/3-dose group was stratified by BMI, with an acquisition time of 5 min (G5), 6 min (G6), and 8 min (G8) for BMI < 25, 25 ≤ BMI ≤ 29, and BMI > 29, respectively. Image quality was subjectively and objectively assessed, and lesion detectability was quantitatively analyzed. Subjective assessments of 1/3-dose and full-dose PET images showed strong agreement among readers (κ > 0.88). In the 1/3-dose group, the Likert scores were above 4. G5, G6, and G8 showed comparable image quality, with G5 demonstrating higher lesion conspicuity than G6 and G8 (p = 0.045). Objective evaluation showed no significant differences in SUVmax, liver SUVmean and TBR between 1/3- and full-dose groups (p > 0.05). No statistical differences were observed in the SUVmax of primary tumor, SUVmean of liver and TBR across all BMI categories between the 1/3-dose and full-dose groups. Lesion detection rates showed no significant difference between the 1/3-dose (93.24%, 193/207) and full-dose groups (94.73%, 198/209) (p = 0.520). A BMI-stratified 1/3-dose regimen is a feasible low-dose alternative with clinically acceptable lesion detectability equivalent to full-dose protocol, potentially expanding the applicability of personalized protocols. This study demonstrated that BMI-stratified 1/3-dose regimens for [18F]FDG total-body PET/CT yielded equivalent outputs compared to the full-dose regimen, which aligns with clinical needs for personalization in dose and BMI. Currently, limited personalized low-dose total-body PET/CT protocols are available, particularly for patients with varied BMI. Reducing the radiotracer dose to 1/3 the standard demonstrated comparable image quality and lesion detectability equivalent to full dose. BMI-stratified 1/3-dose regimen is a clinically feasible low-dose alternative.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.