Abstract
Low cycle fatigue tests in air and LBE containing 10 −6 wt% dissolved oxygen were conducted with T91 steel at 550 °C. T91 was employed in two modifications, one in the as-received state, and the other after alloying FeCrAlY into the surface by pulsed electron beam treatment (GESA process). Tests were carried out with symmetrical cycling ( R = −1) with a frequency of 0.5 Hz and a total elongation Δ ε t/2 between 0.3% and 2%. No influence from LBE on fatigue could be detected. Results in air and LBE showed similar behaviour. Additionally, no difference was observed between surface treated and none treated T91 specimens.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.