Abstract

Monotonic torsional and pure torsional low cycle fatigue (LCF) tests with artificial degradation were performed on duplex stainless steel (CF8M). CF8M is used in pipes and valves in a nuclear reactor coolant system. It was aged at 430°C for 3600 hrs. Through the monotonic and LCF tests, it is found that mechanical properties (i.e., yield strength, strain hardening exponent, strength coefficient etc.) are increased and fatigue life (Nf) is decreased with degradation of material. The relationship between shear strain amplitude (γa) and Nf was proposed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.