Abstract

This paper presents the results of an experimental program to evaluate the low-cycle fatigue-related characteristics of the tensile region of Hollo-bolted angle connections. A summary of a total of 40 tension tests of equivalent T-stub connections is reported. The geometric parameters vary with the bolt gauge width, the column wall's thickness, the bolt type, and the angle's thickness. Based on the experimental test results, the typical failure mechanisms, the hysteretic load-deformation relationship, and the response characteristics such as degradations of strength and energy dissipation capacity of the connections are examined. It is shown that the bolt gauge width and the angle's thickness have significant influences on the failure mode. Energy-based model is proposed to overcome certain geometric limitations and five commonly used damage models are used to predict the damage behavior of connections. Moreover, the low-cycle fatigue life test results are compared with the codified S–N curves through a transformation of the displacement range into the effective stress range. Furthermore, the cumulative damage mechanism is analyzed and the fatigue life formula is obtained. Finally, the results are evaluated and verified by regression analysis. The 90% confidence level was used to test the availability of the regression equation, and the equivalent level of fatigue strength of the tensile region of angle connections is not less than Category 40 (ΔσC = 40 N/mm2). The EC3, BS7608, and AISC-LRFD-1999 specifications are used to evaluate the low-cycle equivalent fatigue strength, and it is found that there is a certain safety reserve when using Category 36.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call