Background Removal of an embedded intraocular foreign body remains challenging due to the risks of bleeding and retinal damage. We present a novel technique to deal with this situation. Case report A 32-year man presented with two months of decreased vision in one eye (best corrected visual acuity of 20/200), a year after a workplace injury that necessitated surgery for an open globe injury. Examination revealed the sequalae of his previous surgery, a subtotal retinal detachment and an embedded intraocular foreign body close to inferior ora serrata at the 6 'o clock position confirmed by imaging. The other eye was normal. A pars plana vitrectomy was performed and the embedded intraocular foreign body was released from surrounding dense adhesions using the vitrectomy probe set at 1000 cuts/minute and 100 mm Hg vacuum, followed by fluid air exchange and endolaser with silicon oil injection. The retinal detachment settled well post-operatively, and at the end of one month, the patient had best corrected visual acuity of 20/60. Conclusions The low-cut, low-vacuum vitrectomy technique can be considered as a safe option for releasing the embedded intraocular foreign body in complex ocular trauma scenarios.