Abstract

In this research, a urea level sensor based on plastic optical fiber was made using the macro bending method and two kinds of configurations. The sensor is made with a gamma and band configuration with a variety of cladding, no cladding, and imperfection and immersed in the urine sample which has different urea. This is aimed at determining the optimal sensor as a urea level sensor. The object measured was a urine sample with different urea concentrations ranging from 336.1 mg/dL to 1384.3 mg/dL, with the same volume for each concentration in the container or sample holder. The light from LED is transmitted through a plastic optical fiber, received by the phototransistor, then amplified by the differential amplifier, and converted by the microcontroller to voltage as the final results on the computer. Changes in urea levels result in changes in the refractive index around the sensor. The results showed that the more imperfection given to the plastic optical fiber sensor with gamma and band configuration, the better the range, sensitivity, and resolution. The best measurements were obtained in the band configuration with PANI-ZnO coating using six imperfections with the range value of 0.514 volts, the sensitivity value of 0.367 mvolt/mg dL-1, and the resolution value of 2.724 mg/dL. The sensor is suitable for urea levels in medical, agricultural, or industrial applications with the advantages of high sensitivity, low cost, and ease of operation.

Highlights

  • IntroductionEnd-stage chronic kidney disease carries an enormous burden of cardiovascular morbidity and mortality [1, 2]

  • Renal function tests have an important role in the diagnosis of early-stage renal function [5]

  • The urea level sensor based on Plastic optical fiber (POF) is made using gamma and band configuration

Read more

Summary

Introduction

End-stage chronic kidney disease carries an enormous burden of cardiovascular morbidity and mortality [1, 2]. According to the Association of Official Agricultural Chemists (AOAC) International, the spectrophotometric method is the official method for urea detection and analysis in ingredients This reagent is usually in solution form, and spectrophotometric equipment is not suitable for on-site detection or field use. Optical fiber sensors have been widely used to detect urea levels. Subsequent research on the fabrication and characterization of urea sensors based on straight configuration plasmon resonance optical fibers coated with silver, silicon, and enzymes in this study requires a relatively long process and time to increase sensor sensitivity [12]. In this research, the detection of urea levels based on POF as a sensing medium was performed by the macro bending method and the imperfection on the sensor. This sensor has the advantages of being easy to operate, easy fabrication, real-time measurement, and being able to be connected to a computer

Principle and Experimental Setup
Results and Discussions
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.