Abstract
This article presents the design, fabrication, experimental characterization, and modeling analysis of the chip-level hotspot targeted liquid impingement jet cooling for high-power electronics. The hotspot targeted jet impingement cooling concept is successfully demonstrated with a chip-level jet impingement cooler with a 1-mm nozzle pitch and 300- $\mu \text{m}$ nozzle diameter fabricated using high-resolution stereolithography (additive manufacturing). The computational fluid dynamics (CFD) modeling and experimental analysis show that the improved hotspot targeted cooler design with fully open outlets can reduce the on-chip temperature difference by 70% compared with the full array cooler at the same pumping power of 0.03 W. The local heat transfer coefficient can achieve $15\times 10^{4}$ W/m2 K with a local flow rate per nozzle of 40 mL/min, requiring a pump power of 0.6 W. The benchmarking study proves that the hotspot targeted cooling is much more energy-efficient than uniform array cooling, with lower temperature difference and lower pump power.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Components, Packaging and Manufacturing Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.