Abstract

Nitrogen-13 labeled ammonia ([13N]NH3) has been used for myocardial perfusion imaging with Positron Emission Tomography for decades. Recent increases to regulatory oversight have led to stricter adherence to Good Manufacturing Practice (GMP) when producing this short half-life (9.97 min) radiopharmaceutical. This has increased production costs. Our cyclotron facility initially developed a manual GMP production method, but it was prone to human error. With increased costs in mind, we developed and validated an Arduino-based device to purifying [13N]NH3 for clinical use. Construction, programming, and GMP validation results are discussed. The automated method was found to produce equivalent quality radiopharmaceutical but was more reproducible and robust.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.