Abstract

The present authors have earlier reported the employment of varying section fixed-fixed beam for achieving lower pull-in voltage with marginal fall in restoring force. Reducing Young’s modulus also reduces the pull-in voltage but with lesser degree of reduction in restoring force. Composite beams are ideal alternatives to achieve decreased Young’s modulus. Hence new varying section composite fixed-fixed beam type RF MEMS switch has been proposed. The main advantage of this RF MEMS switch is that lower pull-in voltages can be achieved with marginal fall in stiction immunity. Spring constant of the proposed switch has been obtained using simulation studies and it has been shown that the spring constant and therefore the pull-in voltage (Vpi) can be considerably reduced with the proposed switch. Simulation studies conducted on the proposed switch clearly demonstrate that the pull-in voltage can be reduced by 31.17% when compared to the varying section monolayer polysilicon fixed-fixed beam. Further this approach enables the designer to have more freedom to design lower pull-in voltage switches with improved stiction immunity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.