Abstract

In this paper, we investigate losses including magnet eddy current loss of permanent magnet synchronous motors with concentrated windings. The 3-D finite element method considering the carrier harmonics of PWM inverters is utilized to calculate the losses in each part of the motor separately. A simple linear magnetic circuit modeling is also introduced to understand the mechanism of the magnet eddy current loss generation. First, the measured and calculated results are compared to verify the validity of the analysis. Next, the variation of the losses due to the stator and rotor shapes are investigated, for instance, concentrated and distributed stator windings, interior and surface mounted permanent magnets. It is clarified that the eddy current loss of the permanent magnet in the concentrated winding motor is much larger than the distributed winding motor. The difference of the loss generation mechanism due to the rotor shape is also clarified.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.