Abstract
In recent years, the number of subways has rapidly increased, as they can effectively alleviate urban traffic congestion. However, subways can also result in thermal pollution problems in underground spaces. The long-term operation of a subway causes thermal accumulation in the surrounding rock of a tunnel, severely affecting the safe and efficient operation of the subway. The metro source heat pump technology is an effective approach to address the foregoing problem. However, currently, the research on its systematic design methods remains inadequate. In particular, studies on the evolution law of heat transfer characteristics of its front-end heat exchangers during years of operation are limited.In this study, a numerical model of a front-end capillary heat exchanger (CHE) is formulated. The model is based on a practical subway source heat pump demonstration project located in a cold area in China. The annual heat transfer characteristics of the CHE under periodic boundary conditions are simulated and analysed. The results reveal that the temperature of the CHE and its vicinity fluctuates periodically and increases annually under typical design conditions. The fluctuation range of CHE wall temperature gradually decreases from 25.0 °C at 0 m from the CHE inlet to 9.6 °C at 10 m from the CHE inlet in the 10th year. A distinct ‘inertia’ phenomenon is observed when the temperature wave is transmitted to the rock surrounding the tunnel. With the increase in the surrounding rock depth from 0 to 25 m, the amplitude of temperature wave gradually decreases from 4.277 to 0.013 °C, and the reduction rate gradually declines from 24 % to 14 %. Meanwhile, the phase delay of temperature wave increased from 0° to 282.40°. Moreover, a critical heat transfer point exists along the CHE tube length, and the heat transfer law and efficiency before and after the critical point differ. Statistics show that the ratio of CHE average heat flux after the critical point to that before the critical point ranges from 1.11 % to 46.16 % in the heating season and from 30.19 % to 46.12 % in the cooling season, respectively. The recommended CHE tube length is determined to be 4.9–6.3 m based on the analysis results. This research can provide reference data and a theoretical basis for the design of front-end heat exchangers of subway source heat pump systems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.