Abstract

ObjectivePlacement of a single transverse stent via the nondominant A1 across the anterior communicating artery (AComA) into the contralateral A2 can provide sufficient neck coverage for wide-necked bifurcation AComA aneurysms. The authors described the feasibility, safety and long-term outcomes of this technique. MethodsBetween January 2015 and February 2018, placement of a single transverse stent via the nondominant A1 was attempted in 17 wide-necked bifurcation AComA aneurysms. The authors reviewed the medical records and radiological studies. ResultsThe technical success rate was 94.1% (16/17). Periprocedural thromboembolic complications occurred in one patient (6.3%) without permanent neurological deficits. The mean clinical follow-up duration was 39.9±9.8 months. No deaths or delayed thromboembolic complications occurred. The mean angiographic follow-up duration was 38.9±9.8 months. The immediate and final follow-up complete occlusion rates were 87.4 and 93.7%, respectively. There was no recanalization during the follow-up period. ConclusionPlacement of a single transverse stent via the nondominant A1 across the AComA into the contralateral A2 is a feasible and relatively safe endovascular technique for the treatment of wide-necked bifurcation AComA aneurysms, with good long-term occlusion rates and a reasonable complication rate, if only the nondominant A1 is applicable.