Abstract

BackgroundTo evaluate the long-term outcomes of Argon laser photocoagulation compared to surgical direct cyclopexy in small-size cyclodialysis cleft patients.MethodsThis is a retrospective study. Small-size cyclodialysis cleft patients who underwent Argon laser photocoagulation and surgical direct cyclopexy were reviewed. The mean follow-up period were 82.4 (range, 61 – 145) months and 99.9 (range, 62 – 184) months in both groups. The comparison of best corrected visual acuity (BCVA), intraocular pressure (IOP), postoperative peak IOP and time to normalization of IOP before and after the treatment.ResultsThe causes of all included 15 cyclodialysis cleft cases were blunt trauma. seven patients underwent Argon laser photocoagulation and eight patients underwent surgical direct cyclopexy. The mean age of included patients was not significantly different (p = 0.38). Preoperatively, the mean logMAR BCVA (standard deviation, SD) was 0.7 (0.2) and 1.1 (0.9) and mean IOP was 4.4 (2.4) mmHg and 3.0 (1.5) mmHg in Argon laser group and surgical direct cyclopexy group (p = 0.24 and p = 0.18, respectively). The extension of cyclodialysis and duration of cyclodialysis cleft were not significantly different between the two groups (p = 0.08 and p = 0.24, respectively). The mean follow-up period were 82.4 (range, 61 – 145) months and 99.9 (range, 62 – 184) months in both groups (p = 0.41). Postoperatively, the mean logMAR BCVA was 0.0 (0.1) and 0.2 (0.3) and mean IOP was 14.5 (3.1) mmHg and 16.8 (2.5) mmHg (p = 0.15 and p = 0.16, respectively). Postoperative peak IOP and time to normalization of IOP were not different between the two groups (p = 0.75 and p = 0.91, respectively).DiscussionIt is necessary to use invasive treatment such as cryotherapy or surgical direct cyclopexy in cyclodialysis cleft with hypotonic maculopathy. In the present study, Argon laser photocoagulation showed good prognosis in a small-size cyclodialysis cleft below 1.5 clock-hours. Considering possible complications and cost of surgical direct cyclopexy, Argon laser can be more beneficial than surgical direct cyclopexy in small-size cyclodialysis cleft below 1.5 clock-hours.ConclusionsThe clinical ourcome of Argon laser photocoagulation seems to be as good as surgical direct cyclopexy in small-size cyclodialysis cleft below 1.5 clock-hours.

Highlights

  • To evaluate the long-term outcomes of Argon laser photocoagulation compared to surgical direct cyclopexy in small-size cyclodialysis cleft patients

  • The clinical ourcome of Argon laser photocoagulation seems to be as good as surgical direct cyclopexy in small-size cyclodialysis cleft below 1.5 clock-hours

  • Harbin reported that three small-size cyclodialysis cleft patients treated by Argon laser photocoagulation showed good prognosis [12]

Read more

Summary

Introduction

To evaluate the long-term outcomes of Argon laser photocoagulation compared to surgical direct cyclopexy in small-size cyclodialysis cleft patients. Cyclodialysis cleft occurs when the ciliary body is detached from the scleral spur. This is usually related to blunt trauma or iatrogenic injury due to ophthalmic surgery. Laser photocoagulation using Argon laser has been used as one of the treatment of choice for repair of cyclodialysis cleft to avoid major intraocular surgeries [10]. Harbin reported that three small-size cyclodialysis cleft patients treated by Argon laser photocoagulation showed good prognosis [12]. We intended to investigate the long-term outcomes of Argon laser photocoagulation compared to surgical direct cyclopexy in small-size cyclodialysis cleft patients

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.