Abstract

To compare the long-term changes in corneal biomechanics, topography, and tomography before and 4 years after corneal cross-linking (CXL) with the Dresden protocol and correlate these changes with visual acuity. In this longitudinal study, 18 eyes of 18 patients with progressive keratoconus who were treated with CXL were included. All patients received a standard ophthalmological examination and were examined by Placido disc-based topography, Scheimpflug tomography, and biomechanical assessments with the Corvis ST (OCULUS Optikgeräte GmbH, Wetzlar, Germany) and Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY) before and 4 years after CXL. The main outcome measures were dynamic corneal response (DCR) parameters obtained from the Corvis ST, corneal hysteresis (CH), corneal resistance factor (CRF), visual acuity, refraction, corneal curvature, and corneal thickness. There were no significant differences in mean visual acuity, refraction, intraocular pressure, corneal topography, corneal astigmatism in both corneal surfaces, maximum keratometry, corneal thickness at apical and thinnest points, thickness profile indices, corneal volume, and specular microscopy before and 4 years after CXL (P > .05). Significant changes were observed in many DCR parameters, including radius at highest concavity and integrated inverse radius, both of which were consistent with stiffening. The CH and CRF values after CXL were not statistically significant. The new parameters using the Corvis ST include integrated inverse concave radius, which showed a significant decrease 1.07 ± 0.93 mm-1, consistent with stiffening. The corneal stiffness parameter at the first applanation, Ambrósio's Relational Thickness to the horizontal profile, deformation amplitude ratio, and Corvis Biomechanical Index as a combined biomechanical screening parameter did not show significant changes. CXL is a minimally invasive treatment option to prevent keratoconus progression over 4 years. Pressure-derived biomechanical parameters obtained from the ORA did not show any change following CXL at 4 years of follow-up, whereas the Corvis ST DCR parameters detected changes in corneal biomechanical properties. [J Refract Surg. 2018;34(12):849-856.].

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.