Abstract
This study provides long-term electrochemical test data of 5×5 cm Ni-YSZ|YSZ|GDC|PSC solid oxide cells in electrolysis mode. Pr0.6Sr0.4CoO3-δ (PSC) is an alternative material for widely used LSC with excellent activity as medium temperature oxygen electrode. The electrolysis was carried out at 800 °C at the cell voltage of 1.5 V. The duration of electrolysis test was 860 hours, at the end of which 18O2 was introduced to the oxygen electrode in the fuel cell mode. An average degradation rate was 16.3 % per 1000 hours of operation. After operation the membrane electrode assembly was analyzed using high resolution electron microscopy (HR-SEM) and time of flight secondary ion mass spectrometry (ToF-SIMS) method. ToF-SIMS was used to conduct an oxygen isotope tracing experiment and to investigate distribution of strontium, silicon and chromium in the electrolyte, Ni-YSZ electrode and PSC electrode. HR-SEM was used to evaluate the changes in microstructure of the electrolysis cell.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.