Abstract
The Gun Test Facility and the accelerator at the DUV-FEL facility are operated as sources for high brightness electron beams ; the first for the Linac Coherent Light Source project and the latter driving an FEL using High Gain Harmonic Generation in the UV. For both accelerators, projections of the longitudinal phase space on the energy coordinate were obtained by varying the phase of an accelerating structure after the gun and measured with a downstream spectrometer dipole. Using an algebraic reconstruction technique, the longitudinal phase space at the entrance to the varied accelerating structure could be reconstructed over a large range of charge from 15 to 600 pC .
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.