Abstract
To report longitudinal home recordings of hemoglobin O(2) saturation by pulse oximetry (Spo(2)) during unperturbed sleep in preterm and term infants. We recorded continuous pulse oximetry during the first 3 minutes of each hour of monitor use (nonevent epochs) for 103 preterm infants born at <1750 g and ≤ 34 weeks postmenstrual age (PMA), and 99 healthy term infants. Median baseline Spo(2) was approximately 98% for both the preterm and term groups. Episodes of intermittent hypoxemia occurred in 74% of preterm and 62% of term infants. Among infants with intermittent hypoxemia, the number of seconds/hour of monitoring <90% Spo(2) was initially significantly greater in the preterm than the term group and declined with age at a similar rate in both groups. The 75(th) to 95(th) percentiles for seconds/hour of Spo(2) <90% in preterm infants were highest at 36 weeks PMA and progressively decreased until 44 weeks PMA, after which time they did not differ from term infants. Clinically inapparent intermittent hypoxemia occurs in epochs unperturbed by and temporally unrelated to apnea or bradycardia events, especially in preterm infants at 36 to 44 weeks PMA.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.