Abstract

The purpose of the present study was to investigate the long-term stability of water-referenced GABA and Glx neurometabolite concentrations in the sensorimotor cortex using MRS and to assess the long-term stability of GABA- and glutamate-related intracortical excitability using transcranial magnetic stimulation (TMS). Healthy individuals underwent two sessions of MRS and TMS at a 3-month interval. A MEGA-PRESS sequence was used at 3T to acquire MRS signals in the sensorimotor cortex. Metabolites were quantified by basis spectra fitting and metabolite concentrations were derived using unsuppressed water reference scans accounting for relaxation and partial volume effects. TMS was performed using published standards. After performing stability and reliability analyses for MRS and TMS, reliable change indexes were computed for all measures with a statistically significant test-retest correlation. No significant effect of time was found for GABA, Glx and TMS measures. There was an excellent ICC and a strong correlation across time for GABA and Glx. Analysis of TMS measure stability revealed an excellent ICC for rMT CSP and %MSO and a fair ICC for 2ms SICI. There was no significant correlation between MRS and TMS measures at any time point. This study shows that MRS-GABA and MRS-Glx of the sensorimotor cortex have good stability over a 3-month period, with variability across time comparable to that reported in other brain areas. While resting motor threshold, %MSO and CSP were found to be stable and reliable, other TMS measures had greater variability and lesser reliability.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call